热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

HB 6212-1989 涡喷涡扇发动机飞行台试验性能修正规范

作者:标准资料网 时间:2024-05-17 12:16:51  浏览:8789   来源:标准资料网
下载地址: 点击此处下载
基本信息
标准名称:涡喷涡扇发动机飞行台试验性能修正规范
中标分类: 航空、航天 >> 航空发动机及其附件 >> 发动机总体
发布日期:1989-05-13
实施日期:1989-12-01
首发日期:1900-01-01
作废日期:1900-01-01
出版日期:1900-01-01
页数:11页
适用范围

没有内容

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 航空 航天 航空发动机及其附件 发动机总体
下载地址: 点击此处下载
【英文标准名称】:Electrostatics.Part4:standardtestmethodsforspecificapplications.Section1:electrostaticbehaviouroffloorcoveringsandinstalledfloors.
【原文标准名称】:静电.第4部分;特殊应用的标准试验方法.第1节:地板铺面和安装地板的静电性能
【标准号】:NFC20-790-4-1-1997
【标准状态】:作废
【国别】:法国
【发布日期】:1997-01-01
【实施或试行日期】:1997-01-20
【发布单位】:法国标准化协会(AFNOR)
【起草单位】:
【标准类型】:()
【标准水平】:()
【中文主题词】:
【英文主题词】:
【摘要】:
【中国标准分类号】:P04
【国际标准分类号】:97_150;59_080_60;17_220_20
【页数】:15P;A4
【正文语种】:其他


Product Code:SAE J2517
Title:Hybrid Iii Family Chest Potentiometer Calibration Procedure
Issuing Committee:Human Biomechanics And Simulations Standards Steering Cmte
Scope:This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent non-linearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is non-linear. Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/(volt/volt) or mm/(mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the non-linearity and others did not. Of those that did correct for the non-linearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Subcommittee (DTES), and led to overall variability in chest compression measurements between laboratories. The intent of this SAE Recommended Practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin to test this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The calibration procedure recommended here uses a two-point calibration and is not intended to correct for the non-linearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also does not require the measurement of a starting position of the potentiometer before each crash test, thus it does not correct for the difference in starting chest geometry between a subject dummy and its design intent. It is intended to be a simple and reproducible calibration procedure which crash test facilities can easily adopt with little or no modifications to their facilities. More complex procedures could in fact address the non-linearity, but at the likely cost of non-adoption by some facilities.

版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1